Show simple item record

dc.contributor.authorGoolaerts, S.
dc.contributor.authorLocatelli, C.
dc.contributor.authorBrecko, J.
dc.contributor.authord'Udekem d'Acoz, C.
dc.contributor.authorFolie, A.
dc.contributor.authorHenrard, A.
dc.contributor.authorMathys, A.
dc.contributor.authorVan De Gehuchte, E.
dc.date2021
dc.date.accessioned2024-03-14T13:25:43Z
dc.date.available2024-03-14T13:25:43Z
dc.identifier.urihttps://orfeo.belnet.be/handle/internal/12798
dc.descriptionX-ray computed tomography (CT-) scanning is revolutionizing the study of extinct organisms. Its non-invasive and non-destructive character makes it currently by far the most potent method to allow fossils to be studied in three dimensions and with unprecedented detail. More importantly, and differing from other 3D techniques, CT-scanning looks through and inside objects, revealing hidden structures and characters. Recent innovations in the field of CT-scanning allow obtaining details up to a few micrometers in resolution, and higher quality images of relatively dense materials, like fossils, even when wholly encased in hard sediment (Keklikoglou et al., 2019). In 2016, the Royal Belgian Institute of Natural Sciences (RBINS) acquired two high-end X-ray CT machines: the micro-CT RX EasyTom and the nano-CT XRE-Tescan UniTom. Both scanners are currently nearly full time in use to help accomplishing the gigantic task of the digitization of the RBINS and Royal Museum for Central Africa (RMCA) type collections, the aim of two multi-year Belspo funded projects, DiSSCo-Fed (2018-2023) and DIGIT-4 (2019-2024). With about 300.000 types and 48.000.000 general specimens, 46.000 and 3.000.000 respectively in their paleontology collections, the results of nearly two centuries of intensive collecting and research, these two Belgian Federal Scientific Institutions (FSI s) are major players in the European framework of scientific research infrastructures for natural history. Digitizing this large number of types, spread across almost the entire Tree of Life, and exhibiting an entire array of differing taphonomies, results in a steadily growing expertise of the RBINS-RMCA micro-CT lab (Brecko et al., 2018). While the newly acquired infrastructure and ongoing digitization projects are primarily oriented towards the digitization of type and figured specimens, these also offer great opportunities for researchers and teachers in various disciplines of paleontology. Targeting on researchers interested in incorporating micro-CT as a technique in their research projects, the current digitization workflow of the RBINS-RMCA micro-CT lab will be presented. While micro-CT offers many advantages, there are also pitfalls and limitations that need to be considered. Based on our expertise, and illustrated by some of our scanning results, important constraints that may block the pathway between your expectations and perfect micro-CT-imaging results that can be fully incorporated into research projects will be presented. Possible effects of some of the most important parameters that may influence the quality of the output, and thus can increase the signal to noise ratio (SNR) will be reviewed, such as the size and shape of the specimen to be scanned, the density of its matrix the specimen is made of or encased in, the presence of certain minerals (e.g. pyrite) and how these may be distributed inside the specimen (e.g. finely disseminated, dense masses or crystals), the best possible resolution in relation to the specimen and preferred output, the time needed to scan a specimen, the choice between machines to be used and their limits and different possible scan settings (e.g. beam power, filters ). Post-processing parameters to be considered are the size of the image stack output (will the computer be able to handle the amount of Gigabytes?), the time needed to render and segment regions of interest and optimize 3D-models, and which format suits best to visualize and export the data (renderings, meshes, videos, virtual sections ). While segmentation may be a time-consuming task, new developments like the incorporation of artificial intelligence (e.g. the Deep Learning function in Dragonfly ORS) offer great potential to reduce the workload in complex segmentation. Many researchers are also teachers. The reason why they may also be particularly interested in the 3D models of the already digitized types that are available on the Virtual Collections platforms of the RBINS (http://virtualcollections.naturalsciences.be/) and RMCA (https://virtualcol.africamuseum.be/). While 3D models are not intended to replace physical specimens, they may become significant teaching aids in both the physical and virtual classroom. In addition, the presence of a steadily growing number of 3D-models and animations of extant animals that are also added to these Virtual Collections, would allow teachers to connect fossils (in general incomplete) with extant (more complete) relatives. Last but not least, while the focus of this communication is largely on micro-CT, some of the many other new techniques that are being tested, used and improved will be highlighted (see e.g. Brecko & Mathys, 2020; Brecko et al., 2014, 2016, 2018; Mathys et al., 2013, 2019 for some examples). Interested in our work, expertise, techniques, equipment, or scans-on-demand? Please do not hesitate to reach out!
dc.languageeng
dc.titleX-ploring new tools for paleontologists: the RBINS-RMCA micro-CT lab at your service!
dc.typeConference
dc.subject.frascatiBiological sciences
dc.audienceScientific
dc.subject.freeBiological collection and data management
dc.source.title7 th INTERNATIONAL GEOLOGICA BELGICA MEETING 2021 Geosciences
Orfeo.peerreviewedNo
dc.identifier.rmca6292


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record