Show simple item record

dc.contributor.authorYang, Y.
dc.contributor.authorZhou, M.
dc.contributor.authorLangerock, B.
dc.contributor.authorSha, M.K.
dc.contributor.authorHermans, C.
dc.contributor.authorWang, T.
dc.contributor.authorJi, D.
dc.contributor.authorVigouroux, C.
dc.contributor.authorKumps, N.
dc.contributor.authorWang, G.
dc.contributor.authorDe Mazière, M.
dc.contributor.authorWang, P.
dc.date2020
dc.date.accessioned2020-07-26T07:25:38Z
dc.date.available2020-07-26T07:25:38Z
dc.identifier.urihttps://orfeo.belnet.be/handle/internal/7570
dc.descriptionThe column-averaged dry-air mole fractions of CO2 (XCO2), CH4 (XCH4) and CO (XCO) have been measured with a Bruker IFS 125HR Fourier-transform infrared (FTIR) spectrometer at Xianghe (39.75∘ N, 116.96∘ E, north China) since June 2018. This paper presents the site, the characteristics of the FTIR system and the measurements. The instrumental setup follows the guidelines of the Total Carbon Column Observing Network (TCCON): the near-infrared spectra are recorded by an InGaAs detector together with a CaF2 beam splitter, and the HCl cell measurements are recorded regularly to derive the instrument line shape (ILS) showing that the instrument is correctly aligned. The TCCON standard retrieval code (GGG2014) is applied to retrieve XCO2, XCH4 and XCO. The resulting time series between June 2018 and July 2019 are presented, and the observed seasonal cycles and day-to-day variations in XCO2, XCH4 and XCO at Xianghe are discussed. In addition, the paper shows comparisons between the data products retrieved from the FTIR measurements at Xianghe and co-located Orbiting Carbon Observatory-2 (OCO-2) and Tropospheric Monitoring Instrument (TROPOMI) satellite observations. The comparison results appear consistent with validation results obtained at TCCON sites for XCO2 and XCH4, while for XCO they highlight the occurrence of frequent high-pollution events. As Xianghe lies in a polluted area in north China where there are currently no TCCON sites, this site can fill the TCCON gap in this region and expand the global coverage of the TCCON measurements. The Xianghe FTIR XCO2, XCH4 and XCO data can be obtained at https://doi.org/10.18758/71021049 (Yang et al., 2019).
dc.languageeng
dc.titleNew ground-based Fourier-transform near-infrared solar absorption measurements of XCO₂, XCH₄ and XCO at Xianghe, China
dc.typeArticle
dc.subject.frascatiEarth and related Environmental sciences
dc.audienceScientific
dc.source.titleEarth System Science Data
dc.source.volume12
dc.source.issue3
dc.source.page1679-1696
Orfeo.peerreviewedYes
dc.identifier.doi10.5194/essd-12-1679-2020


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record