    Contamination in electron observations of the silicon detector on board Cluster/RAPID/IES instrument in Earth's radiation belts and ring current

    Thumbnail
    View/Open
    Kronberg(2016).pdf (2.438Mb)
    Authors
    Kronberg, E.A.
    Rashev, M.V.
    Daly, P.W.
    Shprits, Y.Y.
    Turner, D.L.
    Drozdov, A.
    Dobynde, M.
    Kellerman, A.C.
    Fritz, T.A.
    Pierrard, V.
    Borremans, K.
    Klecker, B.
    Friedel R.
    Show allShow less
    Discipline
    Physical sciences
    Audience
    Scientific
    Date
    2016
    Metadata
    Show full item record
    Description
    Since more than 15 years, the Cluster mission passes through Earth's radiation belts at least once every 2 days for several hours, measuring the electron intensity at energies from 30 to 400 keV. These data have previously been considered not usable due to contamination caused by penetrating energetic particles (protons at >100 keV and electrons at >400 keV). In this study, we assess the level of distortion of energetic electron spectra from the Research with Adaptive Particle Imaging Detector (RAPID)/Imaging Electron Spectrometer (IES) detector, determining the efficiency of its shielding. We base our assessment on the analysis of experimental data and a radiation transport code (Geant4). In simulations, we use the incident particle energy distribution of the AE9/AP9 radiation belt models. We identify the Roederer L values, L⋆, and energy channels that should be used with caution: at 3≤L⋆≤4, all energy channels (40–400 keV) are contaminated by protons (≃230 to 630 keV and >600 MeV); at L⋆≃1 and 4–6, the energy channels at 95–400 keV are contaminated by high-energy electrons (>400 keV). Comparison of the data with electron and proton observations from RBSP/MagEIS indicates that the subtraction of proton fluxes at energies ≃ 230–630 keV from the IES electron data adequately removes the proton contamination. We demonstrate the usefulness of the corrected data for scientific applications.
    Citation
    Kronberg, E.A.; Rashev, M.V.; Daly, P.W.; Shprits, Y.Y.; Turner, D.L.; Drozdov, A.; Dobynde, M.; Kellerman, A.C.; Fritz, T.A.; Pierrard, V.; Borremans, K.; Klecker, B.; Friedel R. (2016). Contamination in electron observations of the silicon detector on board Cluster/RAPID/IES instrument in Earth's radiation belts and ring current. , Space Weather, Vol. 14, Issue 6, 449-462, DOI: 10.1002/2016SW001369.
    Identifiers
    uri: https://orfeo.belnet.be/handle/internal/4263
    doi: http://dx.doi.org/10.1002/2016SW001369
    scopus: 2-s2.0-84977134560
    Type
    Article
    Peer-Review
    Yes
    Language
    eng
    Links
    NewsHelpdeskBELSPO OA Policy

    Browse

    All of ORFEOCommunities & CollectionsBy Issue DateAuthorsTitlesDisciplinesThis CollectionBy Issue DateAuthorsTitlesDisciplines
     

    DSpace software copyright © 2002-2016  DuraSpace
    Send Feedback | Cookie Information
    Theme by 
    Atmire NV