Show simple item record

dc.contributor.authorKeim, C.
dc.contributor.authorEremenko,M.
dc.contributor.authorOrphal, J.
dc.contributor.authorDufour, G.
dc.contributor.authorFlaud, J.-M.
dc.contributor.authorHöpfner M.
dc.contributor.author, Boynard, A.
dc.contributor.authorClerbaux,C.
dc.contributor.authorPayan, S.
dc.contributor.authorCoheur P.-F.
dc.contributor.authorHurtmans, D.
dc.contributor.authorClaude, H.
dc.contributor.authorDe Backer, H.
dc.contributor.author, Dier, H.
dc.contributor.author, Johnson, B.
dc.contributor.authorKelder, H.
dc.contributor.authorKivi, R.
dc.contributor.authorKoide, T.
dc.contributor.authorLópez Bartolomé, M.
dc.contributor.authorLambkin, K.
dc.contributor.authorMoore, D.
dc.contributor.authorSchmidlin, F.J.
dc.contributor.authorStübi, R.
dc.coverage.temporal21st century
dc.date2010
dc.date.accessioned2016-03-07T16:17:04Z
dc.date.accessioned2021-12-09T09:54:23Z
dc.date.available2016-03-07T16:17:04Z
dc.date.available2021-12-09T09:54:23Z
dc.identifier.urihttps://orfeo.belnet.be/handle/internal/8895
dc.descriptionThis paper presents a first statistical validation of tropospheric ozone products derived from measurements of the IASI satellite instrument. Since the end of 2006, IASI (Infrared Atmospheric Sounding Interferometer) aboard the polar orbiter Metop-A measures infrared spectra of the Earth’s atmosphere in nadir geometry. This validation covers the northern mid-latitudes and the period from July 2007 to August 2008. Retrieval results from four different sources are presented: three are from scientific products (LATMOS, LISA, LPMAA) and the fourth one is the pre-operational product distributed by EUMETSAT (version Correspondence to: M. Eremenko(maxim.eremenko@lisa.univ-paris12.fr) 4.2). The different products are derived from different algorithms with different approaches. The difference and their implications for the retrieved products are discussed. In order to evaluate the quality and the performance of each product, comparisons with the vertical ozone concentration profiles measured by balloon sondes are performed and lead to estimates of the systematic and random errors in the IASI ozone products (profiles and partial columns). A first comparison is performed on the given profiles; a second comparison takes into account the altitude dependent sensitivity of the retrievals. Tropospheric columnar amounts are compared to the sonde for a lower tropospheric column (surface to about 6 km) and a “total” tropospheric column (surface to about 11 km). On average both tropospheric columns have small biases for the scientific products, less than 2 Dobson Units (DU) for the lower troposphere and less than 1DU for the total troposphere. The comparison of the still preoperational EUMETSAT columns shows higher mean differences of about 5 DU.
dc.languageeng
dc.publisherIRM
dc.publisherKMI
dc.publisherRMI
dc.relation.ispartofseriesAtmospheric Chemistry and Physics
dc.titleCorrigendum to “Tropospheric ozone from IASI: comparison of different inversion algorithms and validation with ozone sondes in the northern middle latitudes”
dc.typeArticle
dc.subject.frascatiEarth and related Environmental sciences
dc.audienceGeneral Public
dc.audienceScientific
dc.subject.freetropospheric Ozone: IASI (infrared Atmospheric Sounding Interferometer)
dc.subject.freeEumetsat
dc.source.issueAtmospheric Chemistry and Physics
dc.source.page6345
Orfeo.peerreviewedNot pertinent


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record