• Login
     
    View Item 
    •   ORFEO Home
    • Royal Meteorological Institute of Belgium
    • RMI publications
    • View Item
    •   ORFEO Home
    • Royal Meteorological Institute of Belgium
    • RMI publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    "Absolute accuracy and repeatability of the RMIB radiometers for TSI measurements"

    Authors
    Mekaoui, S.
    Dewitte, S.
    Crommelynck, D.
    Joukoff, A.
    Show allShow less
    Discipline
    Earth and related Environmental sciences
    Subject
    total solar irradiance
    SOLCON radiometer
    International Space Station
    SOVAP on the PICARD micro satellite
    Audience
    General Public
    Scientific
    Date
    2004
    Publisher
    IRM
    KMI
    RMI
    Metadata
    Show full item record
    Description
    Radiometers for the measurement of the total solar irradiance from space have been developed by D. Crommelynck at the Royal Meteorological Institute of Belgium (RMIB) since 1970. These radiometers, also used in the set of instruments defining the “World Radiometric Reference”, have successively flown on SPACELAB 1, ATLAS 1, EURECA, ATLAS 2, ATLAS 3, SOHO and HITCHHIKER, among them the SOLCON radiometer on the last STS107 flight. Other radiometers are under construction or integration for the upcoming missions: one as part of the SOVIM experiment on the International Space Station and SOVAP on the PICARD micro satellite. These radiometers have a symmetrical side by side cavity design. They are operated using the differential active cavity radiometric principle. In order to construct a long time series and to detect any variation between two cycles, it is important to know all the instrument parameters and make a clear distinction between what will lead to uncertainty on an absolute level and what guarantees the repeatability of the measurements. The purpose of this paper is to review these parameters; after a description of its principle, the instrumental equation will be established. The electrical parameters and the determination of remaining instrumental parameters are done during the characterisation phase at the RMIB. The results from the DIARAD/VIRGO radiometer on SOHO are presented. The repeatability of the measurements is found to be of the order of 100 ppm after correction of the in-flight aging. The accuracy on an absolute level is about 1.06 W m−2 for DIARAD left cavity. This accuracy is limited by the characterisation accuracy with a dominant role of the precision aperture area determination. The understanding of the behaviour of the DIARAD type instrument allows improving the design of the new radiometers on the upcoming missions.
    Citation
    Mekaoui, S.; Dewitte, S.; Crommelynck, D.; Joukoff, A. (2004). "Absolute accuracy and repeatability of the RMIB radiometers for TSI measurements". , Issue Sol Phys, Vol 224, pp. 237-246, IRM,
    Identifiers
    uri: https://orfeo.belnet.be/handle/internal/8667
    Type
    Article
    Peer-Review
    Not pertinent
    Language
    eng
    Links
    NewsHelpdeskBELSPO OA Policy

    Browse

    All of ORFEOCommunities & CollectionsBy Issue DateAuthorsTitlesDisciplinesThis CollectionBy Issue DateAuthorsTitlesDisciplines
     

    DSpace software copyright © 2002-2016  DuraSpace
    Send Feedback | Cookie Information
    Theme by 
    Atmire NV