• Login
     
    View Item 
    •   ORFEO Home
    • Royal Meteorological Institute of Belgium
    • RMI publications
    • View Item
    •   ORFEO Home
    • Royal Meteorological Institute of Belgium
    • RMI publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A model study of the January 2006 low total ozone episode over Western Europe and comparison with ozone sonde data

    Authors
    Mangold, A.
    Grooß, J.-U.
    De Backer, H.
    Kirner, O.
    Ruhnke, R.
    Müller, R.
    Show allShow less
    Discipline
    Earth and related Environmental sciences
    Subject
    Ozone
    Uccle
    Belgium
    ECMWF
    Audience
    General Public
    Scientific
    Date
    2009
    Publisher
    IRM
    KMI
    RMI
    Metadata
    Show full item record
    Description
    Total column and stratospheric ozone levels at mid-latitudes often reveal strong fluctuations on time scales of days caused by dynamic processes. In some cases the total ozone column is distinctly reduced below climatological values. Here, a very low total ozone episode around 19 January 2006 over Western Europe is investigated when the observed total ozone column over Uccle (BE), measured by a Brewer spectrophotometer, reached a daily minimum of 200 DU, the lowest recorded value at this station. In order to investigate the mechanisms leading to the ozone minimum, the present study used data from (i) six ozone sounding stations in Western and Middle Europe, (ii) ECMWF meteorological fields, (iii) a simulation of the CLaMS model for January 2006, (iv) a multi-year run of the chemistry transport model KASIMA, and (v) a six-year run of the climate chemistry model ECHAM5/MESSy1. The ozone decrease at different heights was quantified and it was determined to what extent different transport mechanisms, and instantaneous insitu chemical ozone depletion contributed to the event. All three models reproduced the evolution and formation of the event. The ozone column decrease between 2=300 and 750K was strongest at Uccle (BE) and De Bilt (nld) with 108 and 103 DU, respectively, and somewhat lower at Hohenpeissenberg (DE), Payerne (CH), Prague (CZ) and Lerwick (UK) with 85, 84, 83 and 74 DU, respectively. Thisanalysis demonstrated that mainldy the displacement of the ozone depleted polar vortex contributed to the ozone column decrease. Advection of ozone-poor low-latitude air massesCorrespondence to: A. Mangold (alexander.mangold@oma.be) was important in the UTLS region. The vertical displacement of isentropes connected with divergence of air out of the column was found to be of minor importance compared to the horizontal transport processes. Severe low total ozone episodes seem to occur when the mentioned mechanisms are superimposed. Instantaneous, in-situ chemical ozone depletion accounted for onldy 2±1% of the overall total ozone decrease at the sounding stations.
    Citation
    Mangold, A.; Grooß, J.-U.; De Backer, H.; Kirner, O.; Ruhnke, R.; Müller, R. (2009). A model study of the January 2006 low total ozone episode over Western Europe and comparison with ozone sonde data. , Issue 0, 6429-6451, IRM,
    Identifiers
    uri: https://orfeo.belnet.be/handle/internal/8809
    Type
    Article
    Peer-Review
    Not pertinent
    Language
    eng
    Links
    NewsHelpdeskBELSPO OA Policy

    Browse

    All of ORFEOCommunities & CollectionsBy Issue DateAuthorsTitlesDisciplinesThis CollectionBy Issue DateAuthorsTitlesDisciplines
     

    DSpace software copyright © 2002-2016  DuraSpace
    Send Feedback | Cookie Information
    Theme by 
    Atmire NV